What a checked pair looks like
Browse the 20 free cards and explanations

A failed 150 kg built-in refrigerator must be pulled from its cabinet enclosure and a new one carried up a flight of stairs. The replacement unit and parts are confirmed. What must be arranged before the job is scheduled?

Answer: A second qualified person plus mechanical aids, such as a stair-rated appliance dolly with straps and floor-protecting glides.

Planning a day's work includes deciding whether special equipment and co-worker help are needed. A 150 kg unit on stairs is far beyond a safe one-person lift, and a built-in unit needs controlled extraction from its enclosure. Booking without a helper or the right dolly means either an unsafe attempt or a wasted trip.

Exam trap: Confirming parts and the appointment time only: parts are already confirmed, but without a helper and stair-rated equipment the job cannot be done safely on arrival.

Standard reference: NOA 2011 A-3.01.05

A conductor disconnected behind a range reads 38 V to ground on a digital multimeter's standard AC volts setting. Which meter function shows whether this is real supply voltage or voltage induced from adjacent wiring?

Answer: The low-impedance (LoZ) AC voltage function: an induced reading collapses toward 0 V under its load, while a real supply holds its voltage.

A standard DMM input is about 10 MΩ, so it can read capacitively coupled 'ghost' voltage on a floating conductor running beside live wires. LoZ mode places a low resistance across the leads, draining the tiny induced charge; a conductor actually connected to the supply keeps its voltage.

Exam trap: A non-contact volt pen: it reacts to the same electric field that creates ghost voltage, so it cannot separate induced voltage from real voltage.

Standard reference: NOA 2011 B-6.01.01

A refrigerator's display goes blank and its control reboots several times a day, while the receptacle holds a steady 120 V. On the main board, one electrolytic capacitor in the power-supply section has a domed top and brown residue at its base. What is the most likely fault?

Answer: That bulged, leaking capacitor in the board's DC power supply has failed, letting the low-voltage rail sag and reset the processor.

Filter capacitors smooth the rectified DC that feeds the board's logic. A domed vent and electrolyte residue are visible signs of failure: capacitance drops, ripple rises and the logic supply dips below the reset threshold. A steady 120 V input during the resets places the fault on the board.

Exam trap: An unstable supply voltage: the receptacle stays at 120 V while the resets happen, so the source is not the cause; the damaged capacitor is.

Standard reference: NOA 2011 B-6.02.03

Which type of appliance diagram shows where components and harness connectors are physically located in the cabinet, rather than how each circuit operates?

Answer: A pictorial (wiring or connection) diagram.

A pictorial diagram draws components roughly where they sit, with wire colours and connector positions, so it guides disassembly and wire tracing. A schematic (ladder) diagram arranges switches and loads between L1 and N by function, making it the tool for circuit logic and voltage checks.

Exam trap: The schematic: it shows how circuits work and is best for troubleshooting logic, but it does not show physical layout or connector location.

Standard reference: NOA 2011 B-6 K8

A refrigerator's 120 V shaded-pole condenser fan motor runs slowly and is too hot to touch. The blade spins freely by hand, the motor receives 120 V, its winding reads 170 Ω (tech sheet: 190–230 Ω) with no path to ground, and it draws twice its rated current. What is the fault?

Answer: Shorted turns in the motor winding; the motor must be replaced.

Shorted turns act like a shorted transformer secondary: they cut the winding's impedance, so current and heat rise while useful flux, torque and speed fall. A freely turning blade and full supply voltage rule out drag and low voltage; the below-spec resistance with doubled current places the fault inside the winding, which cannot be repaired.

Exam trap: Dry or worn bearings, the usual cause of a slow, hot shaded-pole motor: the blade spins freely by hand, and bearing drag would not lower the winding's resistance.

Standard reference: NOA 2011 B-6.03.03

A new wire section is being spliced into a dishwasher door harness that flexes at the hinge each time the door opens. How should the length of the new section be set?

Answer: Long enough that the splices sit away from the hinge flex point and the harness keeps its original slack, with no tension when the door is fully open.

Wire cut too short is pulled tight whenever the door opens, stressing crimps and conductors on every cycle. Placing the splices on a fixed section and keeping the factory service loop lets the harness flex along continuous wire, preventing repeat fatigue breaks.

Exam trap: Cutting it taut for a neat look: a tight harness pulls on the splices every time the door opens and breaks again.

Standard reference: NOA 2011 B-7.01.04

A failed motor run capacitor is labelled 10 µF, 370 VAC. On hand are a 10 µF, 440 VAC capacitor and a 12 µF, 370 VAC capacitor. Which one can be installed?

Answer: The 10 µF, 440 VAC capacitor.

A replacement run capacitor must match the original capacitance, which sets the auxiliary winding's current and phase shift, and must have a voltage rating equal to or higher than the original. A higher voltage rating only adds margin; a different capacitance changes motor performance.

Exam trap: The 12 µF unit: its voltage matches, but 20% more capacitance raises auxiliary-winding current and can overheat the motor.

Standard reference: NOA 2011 B-7 K1

A direct-drive top-load washer drains normally through the pump mounted on its motor, and the motor can be heard running, but there is no agitation and no spin. Black rubber and plastic fragments lie under the machine. What has failed?

Answer: The motor coupling between the motor shaft and the transmission input.

In this design the motor drives the pump directly and drives the transmission through a rubber-and-plastic coupling. Pumping proves the motor turns, and losing both agitation and spin points to the one part common to both drives. Fragments under the washer are the broken coupling.

Exam trap: A worn spin clutch: it affects spin only, so agitation would still work; it cannot explain losing both functions.

Standard reference: NOA 2011 C-8.01.03

A belt-drive washer motor is being repositioned on its slotted mount to set belt tension. Before the mounting bolts are finally tightened, what must be checked, and with what?

Answer: That the motor pulley and the driven pulley run in the same plane, checked with a straightedge laid across both pulley faces.

Misaligned pulleys make the belt run at an angle, so it wears on one edge, squeals and may jump off. A slotted mount lets the motor shift or twist while tension is being set, so alignment is confirmed with a straightedge across both pulley faces before the bolts are tightened.

Exam trap: Checking deflection alone: correct tension does not show whether the motor twisted on its mount, which causes edge wear and thrown belts.

Standard reference: NOA 2011 C-9.01.03

On an empty top-load washer with four corner suspension rods, the gap from tub rim to cabinet top measures 40 mm at three corners and 55 mm at the front-left corner. Which suspension component should be inspected first?

Answer: The front-left suspension rod assembly, for a weak or broken spring, a worn damper or a dislodged end letting that corner sag.

Each rod carries one corner of the tub, so sound rods hold the rim at an even height. A gap 15 mm larger at one corner means the tub hangs lower there, which points to the rod at that corner. Inspect it for a broken or weak spring, a worn damper or an end out of its seat.

Exam trap: The rear-right rod diagonally opposite: the measurements show the front-left corner sitting low, not the rear-right sitting high.

Standard reference: NOA 2011 C-11.01.03

A top-load washer squeaks in rhythm with tub sway. All four suspension rods pass the push-down rebound test, and the squeak comes from where each rod's upper end pivots in its cabinet corner seat. What repair is needed?

Answer: Clean the rod pivot seats and lubricate them with the lubricant the manufacturer specifies; the rods themselves do not need replacing.

Lubricating suspension pivots, linkages and springs prevents noise and wear. The rods damp properly, so the noise is dry friction where they pivot, not a failed rod. Using the specified lubricant matters because some greases attack the plastic or rubber parts of the suspension.

Exam trap: Replacing the rods: each passes the rebound test, so their damping is sound; the noise comes from friction at the dry pivots.

Standard reference: NOA 2011 C-12.01.04

In a time-fill dishwasher or washer inlet valve, which part keeps the fill rate nearly constant across a wide range of household water pressures?

Answer: The flow washer (flow-control washer), a flexible rubber orifice that deforms as pressure changes to hold flow steady.

A time-fill control opens the valve for a set time, so fill volume = flow rate × time. The flow washer's orifice narrows as pressure rises and opens as it falls, keeping flow, and therefore fill volume, close to design across the valve's rated pressure range.

Exam trap: The inlet screen. It only strains sediment from the supply; it does not regulate flow, and when plugged it reduces flow rather than stabilizing it.

Standard reference: NOA 2011 D-13 K2

An ice maker's fill tube keeps freezing solid, even after a new inlet valve was fitted last month. The fill tube heater tests good. Static supply pressure is 103 kPa (15 psi); the valve's rated range is 138–827 kPa (20–120 psi). What is the best course of action?

Answer: Correct the supply so pressure is within the valve's rated range; a third valve would seep and freeze the same way.

Pilot-operated inlet valves rely on line pressure to seat the diaphragm. Below the rated minimum they may not close fully, so water seeps into the fill tube between fills and freezes. The heater is good and a new valve gave the same result, so the 103 kPa supply is the root cause.

Exam trap: Fitting another inlet valve. The new one already failed the same way; below 138 kPa this type of valve can seep, so the supply must be corrected first.

Standard reference: NOA 2011 D-14 K4

In a single-evaporator frost-free refrigerator, what supplies the cooling for the fresh-food compartment?

Answer: Cold air from the freezer evaporator, moved by the evaporator fan through a duct and an adjustable damper (air door) into the fresh-food section.

There is only one coil, in the freezer section. The evaporator fan blows air across it; most goes to the freezer and a metered share passes through the damper into the fresh-food side, then returns to the coil. That is why a fan, duct or damper fault warms the fresh food first.

Exam trap: A separate fresh-food evaporator. Only dual-evaporator models have one; here all fresh-food cooling is freezer air ducted through the damper.

Standard reference: NOA 2011 E-15 K1

After a universal condenser fan motor is fitted, with the blade at its marked depth and orientation, a refrigerator's compressor compartment runs hot. The fan runs at full speed and the coil is clean, but warm air blows out of the grille that used to draw air in. What is the most likely cause?

Answer: The replacement motor turns in the wrong direction, reversing the condenser airflow path.

The compartment is designed for air to enter one side, cross the condenser and compressor, then exit. A fan turning backwards reverses that path and recirculates hot air, so heat rejection drops. A shaded-pole motor is not reversed by swapping leads; fit a motor with the correct rotation or flip a reversible stator per the kit.

Exam trap: A blade fitted backwards or a dirty coil: the blade went back in its marked orientation and the coil is clean, and the airflow reversed only after the motor change.

Standard reference: NOA 2011 E-16.02.04

A window air conditioner is low on charge. An oily, dust-caked spot sits on plain condenser tubing where it touches the fan shroud, and the shroud has a polished wear mark at that point. No other tubing or joint shows oil. What is the most likely cause of the leak?

Answer: Running vibration rubbed the tube against the shroud until the wall wore through (a chafe leak).

Refrigerant oil escapes with the refrigerant and traps dust, so an oily spot marks the leak site. A polished wear mark where the tube contacts the shroud shows the two have been rubbing under compressor and fan vibration until the tube wall wore through. Repair the tube and isolate it from the shroud, or the leak will return.

Exam trap: A cracked brazed joint: joints are common leak sites, but this oil is on plain tubing at a contact point with a wear mark, which points to abrasion.

Standard reference: NOA 2011 F-18.01.02

A refrigerator with a 120 g R-134a charge and no service ports is cooling poorly. Before installing access valves and gauges on its sealed system, what should be done first?

Answer: Confirm a sealed-system fault with non-invasive checks first: frost pattern, condenser and drier temperatures, airflow, defrost and compressor current.

Gauges and hoses on a small critical charge remove a noticeable share of the refrigerant and can admit air and moisture, and every access valve is a possible future leak. Many poor-cooling complaints are airflow, defrost or control faults, so rule those out with temperatures, frost pattern and current draw before entering the sealed system.

Exam trap: Fitting gauges right away to see the pressures: on a small charge the hoses alone change the charge and readings, and the fault may not be in the sealed system at all.

Standard reference: NOA 2011 F-18.03.01

A room air conditioner's rating plate lists R-32, 0.45 kg, with a flammable-refrigerant warning symbol. What does this information require when selecting the recovery machine and cylinder?

Answer: A recovery machine rated for A2L (mildly flammable) refrigerants and a recovery cylinder approved and labelled for flammable refrigerant, used only for R-32.

R-32 is classed A2L: lower toxicity and lower but real flammability. Its vapour can ignite, so the recovery machine must be designed not to ignite it, and the cylinder must be approved and marked for flammable refrigerant. Keeping that cylinder for R-32 alone prevents a mix that cannot be reclaimed.

Exam trap: Using a standard recovery machine because R-32 is only mildly flammable: A2L vapour can still ignite, so the equipment must be rated for it.

Standard reference: NOA 2011 F-19.01.01

A refrigerator compressor has failed with its windings shorted to ground. The oil drained from it is black and smells sharp and burnt. A new compressor and drier are ready to install. What additional work does this evidence call for?

Answer: Treat it as a burnout: clean the acid and sludge out of the system (approved flush, or replace contaminated parts) before fitting the new compressor and drier.

A grounded winding with black, burnt-smelling oil means the motor overheated and the oil and insulation broke down into acids and sludge. These stay in the condenser, evaporator and capillary; left there, they attack the new compressor's windings and plug the new drier. A mechanical failure with clean oil would need only the compressor and drier.

Exam trap: Treating it as a mechanical failure needing only a compressor and drier: clean oil would allow that, but black, burnt oil shows acid that would destroy the new compressor.

Standard reference: NOA 2011 F-20 K4

A refrigerator's rating plate specifies a charge of 4.5 oz of R-134a. The refrigerant cylinder sits on an electronic scale that reads 6.250 kg before charging. At what scale reading should charging stop?

Answer: At 6.122 kg: 4.5 oz is about 128 g, so 6.250 − 0.128 = 6.122 kg.

Capillary-tube appliances are critically charged, so the exact rating-plate weight must go in. One ounce is 28.35 g, so 4.5 oz × 28.35 = 127.6 g, about 128 g. The scale falls as refrigerant leaves the cylinder, so stop at 6.250 − 0.128 = 6.122 kg.

Exam trap: Adding the charge to the reading (6.378 kg): the cylinder loses weight as it charges, so the scale counts down from 6.250 kg.

Standard reference: NOA 2011 F-20.04.02