Gasfitter – Class B math scenarios
MathQuestion 4 of 1070% to goContinue at question 4
10 questions
2 right · 1 wrong · 7 to do- 1Clocking a residential meter
- 2Furnace input to cover a heat loss
- 3Developed length for the sizing table
- 4The heating value of propane
- 5Temperature rise through a furnace
- 6Recovery of a storage water heater
- 7Total propane load for a house
- 8Tankless heater flow in U.S. gpm
- 9Gas held in a run of pipe
- 10Test gauge reading after the pipe warms
Part 1
2 right · 1 wrong · 7 to do- 1Clocking a residential meterInput = CFH × HV · Procedural and application
- 2Furnace input to cover a heat lossInput = output ÷ efficiency · Procedural and application
- 3Developed length for the sizing tableDeveloped length · Critical thinking
- 4The heating value of propaneHeat content · Knowledge and recall
- 5Temperature rise through a furnaceΔT = Btuh ÷ (1.08 × CFM) · Procedural and application
- 6Recovery of a storage water heaterOutput = ΔT × 8.33 × 60 × USGPM · Procedural and application
- 7Total propane load for a houseCFH = input ÷ HV · Procedural and application
- 8Tankless heater flow in U.S. gpmConversion · Procedural and application
- 9Gas held in a run of pipeVolume of a cylinder · Procedural and application
- 10Test gauge reading after the pipe warmsGauge pressure reading · Critical thinking
By question type
- Procedural and application2 of 7 done
- Critical thinking1 of 2 done
- Knowledge and recall0 of 1 done