MathOnline Red Seal Exam Preparation, built on official standards
Gasfitter – Class B formula sheet, conversions and acronyms
MathReference115 formulas · 81 conversions · 51 acronyms
On the exam
- Official formula sheet
- Given at the exam
- Conversions
- Partly given
- Acronyms
- You get the list
- Calculator
- The same calculator as here
On the exam
Formula sheetGiven at the exam
CalculatorThe same as here
Formulas
115 formulasFrom the official Gasfitter - Class B formula sheet. The same sheet is printed for you at the exam.
% of CO 2(stoich CO2) / (1 + ( (% excess air) / (100) ))
Actuator position (%)(IS − FCS) / (FOS − FCS)
BtuhM × C × Δ T
CFH(output) / (efficiency) ÷ HV
CFH(output) / (HV)
CFH(dial) / (SPR) × 3 600 × PF
CFH(3 600 × dial) / (SPR)
CFM(Btuh × E) / (1.08 × Δ T)
CO 2 volume (combustion)output × ft3 of CO2 / ft3 of gas ÷ HV
Fuse ratingA × SF
Gauge pressure reading( (( p + 14.7 ) × ( △ T + T )) / (Tamb + T) ) − 14.7
Input (Btuh)(output) / (efficiency)
Input (Btuh)( ([ Pbase + dial ] × CFH) / (Pbase) ) × HV
Input (Btuh)CFH × HV
Input (Btuh)( (3 600 × BarG) / (SPR) ) × ( (Pbase + BarG) / (Pbase) ) × HV
Net stack temperaturedownstream flue T − Tamb
Output (Btuh)Δ T × 8.33 × 60 × USGPM
Output (Btuh)# BHP × 33 500 × # boilers
PowerV × A
Pressure factor(Pbase + BarG) / (Pbase)
Pressure test( ([ comb. rate × # cyl. ] + ( 136.354 × 14.7 )) / ([ Ptest × # cyl. ] + 136.354) ) − 14.7
Purge time(CFM × # air changes) / (SCFM)
Seconds per rotation(CFH) / (( 3 600 × PF )) × dial
Traveloffset D × 1.414
Volt ‑ ampereI × E
VoltageI × R
Circleπ r2
RectangleL × W
Sphere4 π r2
Triangle(B × H) / (2)
CuboidL × W × H
Cylinderπ r2 H
Sphere(4 π r3) / (3)
°Cdegree Celsius
°Fdegree Fahrenheit
°Kdegree Kelvin
Aampere
BHPboiler horsepower
BTUBritish thermal unit
BtuhBritish thermal units per hour
CFHcubic feet per hour
CFMcubic feet per minute
ft.foot
ft 2square foot
ft 3cubic foot
gal.imperial gallon
gpmimperial gallons per minute
hrhour
in.inch
in 2square inch
in 3cubic inch
kgkilogram
kPakilopascal
kPaGkilopascal gauge
kWkilowatt
Llitre
lb.pound
lbfpound - force
mmetre
m 2square metre
m 3cubic metre
minminute
mmmillimetre
psipounds per square inch
psiapounds per square inch absolute
psigpounds per square inch gauge
ssecond
SCFMstandard cubic feet per minute
SPRseconds per rotation
tton (ice melted over a 24-hour period)
USGAmerican gallon
USGPMAmerican gallons per minute
Vvolt
VAvolt-ampere
Wwatt
∆Ttemperature difference
Bbase
BarGbar gauge
Cspecific heat of fluid
CO 2carbon dioxide
Ddistance
FCSfully closed signal
FOSfully open signal
Hheight
HVheating value
Icurrent (in amperes)
ISinput signal
Llength
Mmass of fluid per hour
Ppressure
P basebase/atmospheric pressure
P testtest pressure
PFpressure factor
rradius
Rresistance (in ohms)
SFsafety factor
stoichstoichiometric
Ttemperature
T ambambient temperature
Wwidth
π3.1416
1 ft 3 of water6.228 gal.
1 USG8.33 lb.
45° offset1.414
12 000 BTU (cooling capacity)1 t
Air- fuel ratio14.7
Base/atmospheric pressure14.73 psig/psia
Boiler horsepower (BHP)33 500
BTU per 1 000 W (single phase)3.414
BTU per 1 000 W (three phase)1.73
Heat content - natural gas1 000 BTU/ft 3
Heat content - propane2 500 BTU/ft 3
Pressure head conversion unit0.433 psi/ft.
Specific heat of air1.08
Standard for air at sea level4.5
General formulas
% of CO 2(stoich CO2) / (1 + ( (% excess air) / (100) ))
Actuator position (%)(IS − FCS) / (FOS − FCS)
BtuhM × C × Δ T
CFH(output) / (efficiency) ÷ HV
CFH(output) / (HV)
CFH(dial) / (SPR) × 3 600 × PF
CFH(3 600 × dial) / (SPR)
CFM(Btuh × E) / (1.08 × Δ T)
CO 2 volume (combustion)output × ft3 of CO2 / ft3 of gas ÷ HV
Fuse ratingA × SF
Gauge pressure reading( (( p + 14.7 ) × ( △ T + T )) / (Tamb + T) ) − 14.7
Input (Btuh)(output) / (efficiency)
Input (Btuh)( ([ Pbase + dial ] × CFH) / (Pbase) ) × HV
Input (Btuh)CFH × HV
Input (Btuh)( (3 600 × BarG) / (SPR) ) × ( (Pbase + BarG) / (Pbase) ) × HV
Net stack temperaturedownstream flue T − Tamb
Output (Btuh)Δ T × 8.33 × 60 × USGPM
Output (Btuh)# BHP × 33 500 × # boilers
PowerV × A
Pressure factor(Pbase + BarG) / (Pbase)
Pressure test( ([ comb. rate × # cyl. ] + ( 136.354 × 14.7 )) / ([ Ptest × # cyl. ] + 136.354) ) − 14.7
Purge time(CFM × # air changes) / (SCFM)
Seconds per rotation(CFH) / (( 3 600 × PF )) × dial
Traveloffset D × 1.414
Volt ‑ ampereI × E
VoltageI × R
Area formulas
Circleπ r2
RectangleL × W
Sphere4 π r2
Triangle(B × H) / (2)
Volume formulas
CuboidL × W × H
Cylinderπ r2 H
Sphere(4 π r3) / (3)
Measurement unit abbreviations
°Cdegree Celsius
°Fdegree Fahrenheit
°Kdegree Kelvin
Aampere
BHPboiler horsepower
BTUBritish thermal unit
BtuhBritish thermal units per hour
CFHcubic feet per hour
CFMcubic feet per minute
ft.foot
ft 2square foot
ft 3cubic foot
gal.imperial gallon
gpmimperial gallons per minute
hrhour
in.inch
in 2square inch
in 3cubic inch
kgkilogram
kPakilopascal
kPaGkilopascal gauge
kWkilowatt
Llitre
lb.pound
lbfpound - force
mmetre
m 2square metre
m 3cubic metre
minminute
mmmillimetre
psipounds per square inch
psiapounds per square inch absolute
psigpounds per square inch gauge
ssecond
SCFMstandard cubic feet per minute
SPRseconds per rotation
tton (ice melted over a 24-hour period)
USGAmerican gallon
USGPMAmerican gallons per minute
Vvolt
VAvolt-ampere
Wwatt
Values
∆Ttemperature difference
Bbase
BarGbar gauge
Cspecific heat of fluid
CO 2carbon dioxide
Ddistance
FCSfully closed signal
FOSfully open signal
Hheight
HVheating value
Icurrent (in amperes)
ISinput signal
Llength
Mmass of fluid per hour
Ppressure
P basebase/atmospheric pressure
P testtest pressure
PFpressure factor
rradius
Rresistance (in ohms)
SFsafety factor
stoichstoichiometric
Ttemperature
T ambambient temperature
Wwidth
Constants
π3.1416
1 ft 3 of water6.228 gal.
1 USG8.33 lb.
45° offset1.414
12 000 BTU (cooling capacity)1 t
Air- fuel ratio14.7
Base/atmospheric pressure14.73 psig/psia
Boiler horsepower (BHP)33 500
BTU per 1 000 W (single phase)3.414
BTU per 1 000 W (three phase)1.73
Heat content - natural gas1 000 BTU/ft 3
Heat content - propane2 500 BTU/ft 3
Pressure head conversion unit0.433 psi/ft.
Specific heat of air1.08
Standard for air at sea level4.5
On the exam
ConversionsPartly given
Conversions
81 conversions°C → °F× 1.8 and add 32
°C → °K× 1 and add 273
decimal → second× 60
ft ^(2) → in ^(2)× 144
ft ^(3) → USG× 7.48
kg → lb.× 2.205
kPa → lbf/ft ^(2)× 20.88
kPa → lbf/in ^(2) (psi)× 0.1450
kPaG → lbf/in ^(2) gauge (psig)× 0.1450
L → USG× 0.2200
L/min → USGPM× 0.2641
L/s → gpm× 13.20
m → ft.× 3.281
m ^(2) → ft ^(2)× 10.76
m ^(3) → ft ^(3)× 35.31
mm → in.× 0.03937
1 psi6.895 kPa
1 kPa0.1450 psi
1 bar100 kPa
1 bar14.50 psi
1 atm101.3 kPa
1 atm14.70 psi
1 in w.c.249.1 Pa
1 ft of water0.4335 psi
1 in Hg3.386 kPa
1 lbf4.448 N
1 kN224.8 lbf
1 L/s60 L/min
1 L/s3.6 m³/h
1 L/s15.85 US gpm
1 L/s13.20 imp gpm
1 US gpm3.785 L/min
1 imp gpm4.546 L/min
1 cfm0.4719 L/s
1 cfm1.699 m³/h
1 m³/h0.5886 cfm
1 hp746 W
1 kW1.341 hp
1 kW3 412 Btu/h
1 Btu/h0.2931 W
1 Btu1.055 kJ
1 ton of refrigeration12 000 Btu/h
1 ton of refrigeration3.517 kW
1 kWh3.6 MJ
1 therm100 000 Btu
1 boiler hp33 475 Btu/h
1 m³1 000 L
1 m³35.31 ft³
1 m³1.308 yd³
1 yd³27 ft³
1 ft³28.32 L
1 ft³7.481 US gal
1 ft³6.229 imp gal
1 L0.2642 US gal
1 L0.2200 imp gal
1 US gal3.785 L
1 imp gal4.546 L
1 in³16.39 mL
°C to °F× 1.8, then + 32
°F to °C− 32, then ÷ 1.8
°C to K+ 273.15
A difference of 1 °C1.8 °F
Water freezes0 °C = 32 °F
Water boils (sea level)100 °C = 212 °F
1 in25.4 mm
1 ft304.8 mm
1 ft0.3048 m
1 yd0.9144 m
1 m3.281 ft
1 m39.37 in
1 km0.6214 mi
1 mi1.609 km
Water1 000 kg/m³ = 1 kg/L
Water62.4 lb/ft³
Water8.34 lb per US gal
Water10.0 lb per imp gal
Steel7 850 kg/m³ = 490 lb/ft³
Steel plate7.85 kg per m² per mm
Concrete2 400 kg/m³ = 150 lb/ft³
1 kg/m³0.06243 lb/ft³
1 lb/ft³16.02 kg/m³
On your sheet
°C → °F× 1.8 and add 32
°C → °K× 1 and add 273
decimal → second× 60
ft ^(2) → in ^(2)× 144
ft ^(3) → USG× 7.48
kg → lb.× 2.205
kPa → lbf/ft ^(2)× 20.88
kPa → lbf/in ^(2) (psi)× 0.1450
kPaG → lbf/in ^(2) gauge (psig)× 0.1450
L → USG× 0.2200
L/min → USGPM× 0.2641
L/s → gpm× 13.20
m → ft.× 3.281
m ^(2) → ft ^(2)× 10.76
m ^(3) → ft ^(3)× 35.31
mm → in.× 0.03937
Pressure and force
1 psi6.895 kPa
1 kPa0.1450 psi
1 bar100 kPa
1 bar14.50 psi
1 atm101.3 kPa
1 atm14.70 psi
1 in w.c.249.1 Pa
1 ft of water0.4335 psi
1 in Hg3.386 kPa
1 lbf4.448 N
1 kN224.8 lbf
Flow
1 L/s60 L/min
1 L/s3.6 m³/h
1 L/s15.85 US gpm
1 L/s13.20 imp gpm
1 US gpm3.785 L/min
1 imp gpm4.546 L/min
1 cfm0.4719 L/s
1 cfm1.699 m³/h
1 m³/h0.5886 cfm
Power and energy
1 hp746 W
1 kW1.341 hp
1 kW3 412 Btu/h
1 Btu/h0.2931 W
1 Btu1.055 kJ
1 ton of refrigeration12 000 Btu/h
1 ton of refrigeration3.517 kW
1 kWh3.6 MJ
1 therm100 000 Btu
1 boiler hp33 475 Btu/h
Volume
1 m³1 000 L
1 m³35.31 ft³
1 m³1.308 yd³
1 yd³27 ft³
1 ft³28.32 L
1 ft³7.481 US gal
1 ft³6.229 imp gal
1 L0.2642 US gal
1 L0.2200 imp gal
1 US gal3.785 L
1 imp gal4.546 L
1 in³16.39 mL
Temperature
°C to °F× 1.8, then + 32
°F to °C− 32, then ÷ 1.8
°C to K+ 273.15
A difference of 1 °C1.8 °F
Water freezes0 °C = 32 °F
Water boils (sea level)100 °C = 212 °F
Length
1 in25.4 mm
1 ft304.8 mm
1 ft0.3048 m
1 yd0.9144 m
1 m3.281 ft
1 m39.37 in
1 km0.6214 mi
1 mi1.609 km
Density and unit mass
Water1 000 kg/m³ = 1 kg/L
Water62.4 lb/ft³
Water8.34 lb per US gal
Water10.0 lb per imp gal
Steel7 850 kg/m³ = 490 lb/ft³
Steel plate7.85 kg per m² per mm
Concrete2 400 kg/m³ = 150 lb/ft³
1 kg/m³0.06243 lb/ft³
1 lb/ft³16.02 kg/m³
On the exam
AcronymsYou get the list
Acronyms
51 acronymsThe following acronyms used in this trade may be on its Red Seal exam. They will also be provided with the exam sitting. The official list (PDF)
ABSacrylonitrile butadiene styrene
ACRair conditioning and refrigeration
AFUEannual fuel utilization efficiency
AHJauthority having jurisdiction
ANSIAmerican National Standards Institute
BFSbattery-filling system
CAPScombustion air proving switch
CECCanadian Electrical Code
cfmcubic feet/minute
CSACanadian Standards Association
CSSTcorrugated stainless steel tube
DFMAHdirect-fired make-up air heater
DWVdrain, waste, vent
EACelectronic air cleaner
ECMelectronically commutated motor
EFelectrofusion
FARCfuel air ratio control
FLAfull load amps
FVSfuel valve switch
HGPShigh gas pressure switch
HSIhot surface ignitor
HWAhigh water alarm
I.D.inside diameter
IRinfrared
LGPSlow gas pressure switch
LPliquid propane
LWAlow water alarm
LWCOlow water cut-off
NBCNational Building Code
NPSnominal pipe size
O.D.outside diameter
OHSOccupational Health and Safety
OHSAOccupational Health and Safety Act
PBproportional band
PIDproportional integral derivative
POCproof of closure
ppmparts per million
psiapounds per square inch absolute
psigpounds per square inch gauge
QNFTquantitative fit test
sprseconds per revolution
SSOVsafety shut-off valve
USGU.S. gallon
USWGU.S. water gallon
UVultraviolet
VACVolts/Alternative Current
VDCVolts/Direct Current
VFDvariable frequency drive
VPSvalve proving system
w.c.water column
WHMISWorkplace Hazardous Materials Information System
ABSacrylonitrile butadiene styrene
ACRair conditioning and refrigeration
AFUEannual fuel utilization efficiency
AHJauthority having jurisdiction
ANSIAmerican National Standards Institute
BFSbattery-filling system
CAPScombustion air proving switch
CECCanadian Electrical Code
cfmcubic feet/minute
CSACanadian Standards Association
CSSTcorrugated stainless steel tube
DFMAHdirect-fired make-up air heater
DWVdrain, waste, vent
EACelectronic air cleaner
ECMelectronically commutated motor
EFelectrofusion
FARCfuel air ratio control
FLAfull load amps
FVSfuel valve switch
HGPShigh gas pressure switch
HSIhot surface ignitor
HWAhigh water alarm
I.D.inside diameter
IRinfrared
LGPSlow gas pressure switch
LPliquid propane
LWAlow water alarm
LWCOlow water cut-off
NBCNational Building Code
NPSnominal pipe size
O.D.outside diameter
OHSOccupational Health and Safety
OHSAOccupational Health and Safety Act
PBproportional band
PIDproportional integral derivative
POCproof of closure
ppmparts per million
psiapounds per square inch absolute
psigpounds per square inch gauge
QNFTquantitative fit test
sprseconds per revolution
SSOVsafety shut-off valve
USGU.S. gallon
USWGU.S. water gallon
UVultraviolet
VACVolts/Alternative Current
VDCVolts/Direct Current
VFDvariable frequency drive
VPSvalve proving system
w.c.water column
WHMISWorkplace Hazardous Materials Information System