Pass Your Red Seal
Exams

Online Red Seal Exam Preparation, built on official standards

only $14.99

  • Full trade access
  • 12 months
Unlock full access

Pay once, good for a full year.

Gasfitter – Class B

Built on official standards for your trade

Practice exams split like the real exam.
Every answer explained.

only $14.99

  • Full trade access
  • 12 months
Unlock full access

Pay once, good for a full year.

4
Practice exams
400
Questions
200
Flashcards
1,000+
Flashcard Match
50+
Trade math
100+
Simulations
Try Gasfitter – Class B free12 sample questions now, or Exam 1 with a free account12 sample questionsFree Exam 1

Practice exams

4 exams · 100 questions each

Exam 1 is free. Create a free account and retake it as often as you like, with no expiry. How it works

4 practice exams and 400 original practice questions with answers and explanations, plus 200 flashcards in two exam-weighted sets, for the 100-question Gasfitter – Class B Red Seal exam. Timed or untimed, with pause and resume. 100 questions in the real exam · 4 hours · 70% pass mark.

Gasfitter – Class B sample exam questions

Take them as an exam

12 free practice questions with answers and explanations. No account needed.

Sample 1 Gasfitter – Class B, free sample

A boiler's burner switch is off, but its pump has a separate supply and its piping remains pressurized. Before opening the pump assembly, which preparation controls the identified energy sources?

Answer Isolate both supplies and relieve trapped pressure.
Why Electrical isolation must include both supplies, with stored pressure relieved and isolation verified under the equipment procedure. Keeping pressure leaves stored energy. The burner or pump control stops operation but does not isolate the separate electrical feeds.
2. For a fuel-piping run, what is the distinction between operating pressure and allowable pressure drop used for sizing?
Answer Operating pressure is service pressure; drop is loss along the run.
Why Service pressure and allowable loss are separate sizing inputs. Rated strength is the material pressure limit, not the operating pressure. Neither static nor dynamic inlet pressure alone defines the drop; pressure loss requires a difference between locations under the relevant flow.
3. Use this supplied sizing extract for the design gas and pressure: at 18 m, sizes 20, 25 and 32 carry 42, 70 and 115 kW; at 24 m they carry 35, 60 and 98 kW. The method requires the next longer row. For a 20 m run serving 66 kW, what is the smallest listed size?
Answer Use size 32 from the longer, 24 m table row.
Why A 20 m run uses the 24 m row. Its 60 kW size-25 capacity is below 66 kW, so size 32 is required. Size 25 at 18 m uses the wrong row, and size 20 fails even on that shorter row. The extract is scenario data, not a universal sizing table.
4. In appliance vent categories, which combination describes Category IV operation?
Answer Positive vent pressure with condensation expected.
Why Category IV combines positive vent pressure with condensing operation. Category III shares positive pressure but is noncondensing; Category II combines nonpositive pressure and condensation; Category I is nonpositive and noncondensing. These categories guide vent-system suitability.
5. A proposed vent route requires a system suitable for positive pressure and 80°C flue gas. The appliance permits either of two listed systems: P is rated to 65°C; C is rated to 90°C. Both meet the pressure requirement. Which selection is supported?
Answer Choose C: its pressure and temperature ratings both cover the duty.
Why C alone meets the supplied 80°C duty and pressure requirement. P passes pressure but fails temperature. Appliance approval does not erase a stated service limit. Condensing positive-pressure systems exist, so that characteristic does not disqualify C.
6. What is the control function of a modulating fuel-air actuator, compared with a two-position actuator?
Answer Modulation allows commanded positions between the travel limits.
Why Modulating action permits intermediate positions. Restricting operation to endpoints describes two-position action. Neither continuously varying nor holding arbitrary intermediate positions is the defining capability of a two-position actuator.
7. During installation, a combustion-control transmitter is moved from terminal 6 to terminal 8 under an approved revision. Which drawing record should be issued?
Answer Issue an as-built identifying terminal 8 and tracing its approved revision.
Why An as-built must show terminal 8 and the approved revision. Terminal 6 is obsolete. An unidentified revised schematic loses approval traceability; changing the inspection date alone leaves the old connection in place.
8. What is the difference between a gas appliance's input rating and its useful output rating?
Answer Input is fuel energy per time; output is useful heat per time.
Why Both ratings are energy rates. Swapping the rates reverses their meaning. Volume rates require heating-value information to become heat rates, and total stored energy lacks the time basis of a power rating.
9. A supplied valve schedule calls for a normally closed safety shutoff valve that closes when power is removed, rated for the stated fuel and pressure. Which selection matches the required fail action?
Answer Use the fuel-rated valve that closes when electrical power fails.
Why Only the de-energize-to-close valve implements the stated failure action. Opening or holding position on power loss does not. A valve requiring electrical power to close cannot provide the specified closure when that power is absent.
10. A supplied pneumatic test procedure requires a 100 kPa test and an instrument whose full scale is at least the test pressure, with resolution no coarser than 1 kPa. Gauges available are 60/1, 160/1, 250/5 and 600/10 kPa range/resolution. Which qualifies?
Answer Use the 160 kPa range gauge with 1 kPa resolution.
Why The 160/1 instrument covers 100 kPa and resolves 1 kPa. The 60/1 gauge cannot cover the test. The 250/5 and 600/10 instruments have adequate range but insufficient resolution. These are supplied project criteria, not universal code gauge rules.
11. During scheduled inspection, a vent-support bracket is loose and the vent sags below its required drainage line. The service instruction requires support restoration before return to service. What maintenance finding must be addressed?
Answer Restore the support and recover the specified continuous fall.
Why The instruction requires restored support and drainage geometry. Supporting the current sag retains a liquid pocket. Raising either end while retaining the low point also fails to establish continuous fall.
12. What does a rising pressure difference across a cleanable air filter usually indicate when airflow and measurement locations are unchanged?
Answer Higher filter resistance under the same measured airflow.
Why At the stated unchanged airflow, greater differential indicates increased resistance. Decreased resistance has the wrong direction. Either explanation invoking changed airflow contradicts the stem; loading is a common cause to inspect.

Start free

Interactive simulations

Animated simulations built for Red Seal trades. See inside pumps, transmissions, air brakes, gears and heavy machinery, watch every part move, and interact with each one as it runs.

Diagrams and symbols

Learn to read the diagrams and schematic symbols used in your trade.

How things work

Animated section drawings show what happens inside the equipment as it runs.

Terminology

Learn the correct name and job of every part.

Exam breakdown

Red Seal practice tests and exam prep

The official Gasfitter – Class B Red Seal exam, also called the interprovincial (IP) exam, has 100 questions across 7 topic blocks. Open a block to see its tasks and subtasks.

100
Multiple choice questions
4 hours
Writing time
70%
Pass mark
Major Work Activity% of examReal examPractice bank
APerforms common occupational skills7%728

A-1 · Performs safety-related functions

2 official exam questions · 8 in the practice bank

  • A-1.01 Maintains safe work environment
  • A-1.02 Uses personal protective equipment (PPE) and safety equipment

A-2 · Uses tools and equipment

2 official exam questions · 8 in the practice bank

  • A-2.01 Uses hand and power tools
  • A-2.02 Uses technical instruments and testers
  • A-2.03 Uses access equipment
  • A-2.04 Operates lifting, rigging and hoisting equipment

A-3 · Organizes work

3 official exam questions · 12 in the practice bank

  • A-3.01 Interprets documents
  • A-3.02 Selects systems, equipment and components
  • A-3.03 Plans for installation, service and maintenance

A-4 · Uses communication and mentoring techniques

0 official exam questions · 0 in the practice bank

  • A-4.01 Uses communication techniques
  • A-4.02 Uses mentoring techniques
BInstalls fuel piping and tubing systems14%1456

B-5 · Selects and installs piping for fuel systems

7 official exam questions · 28 in the practice bank

  • B-5.01 Selects piping for fuel systems
  • B-5.02 Prepares piping for fuel systems
  • B-5.03 Installs piping for fuel systems

B-6 · Selects and installs tubing for fuel systems

7 official exam questions · 28 in the practice bank

  • B-6.01 Selects tubing for fuel systems
  • B-6.02 Prepares tubing for fuel systems
  • B-6.03 Installs tubing for fuel systems
CInstalls venting and air supply systems15%1560

C-7 · Selects and installs venting systems

6 official exam questions · 24 in the practice bank

  • C-7.01 Selects materials for venting systems
  • C-7.02 Prepares materials for venting systems
  • C-7.03 Installs venting systems

C-8 · Selects and installs air supply systems

5 official exam questions · 20 in the practice bank

  • C-8.01 Selects materials for air supply systems
  • C-8.02 Prepares materials for air supply systems
  • C-8.03 Installs air supply systems

C-9 · Selects and installs draft control systems

4 official exam questions · 16 in the practice bank

  • C-9.01 Selects components for draft control systems
  • C-9.02 Installs components for draft control systems
DInstalls controls and electrical systems15%1560

D-10 · Selects and installs combustion control systems

3 official exam questions · 12 in the practice bank

  • D-10.01 Selects combustion control components
  • D-10.02 Installs combustion control components

D-11 · Selects and installs flame safeguard systems

4 official exam questions · 16 in the practice bank

  • D-11.01 Selects flame safeguard components
  • D-11.02 Installs flame safeguard components

D-12 · Selects and installs operating control systems

4 official exam questions · 16 in the practice bank

  • D-12.01 Selects operating control components
  • D-12.02 Installs operating control components

D-13 · Selects and installs electrical systems

3 official exam questions · 12 in the practice bank

  • D-13.01 Selects electrical components
  • D-13.02 Installs electrical components

D-14 · Selects and installs automation and instrumentation control systems

1 official exam question · 4 in the practice bank

  • D-14.01 Selects automation and instrumentation control components
  • D-14.02 Installs automation and instrumentation control components
EInstalls and converts fuel systems, appliances and ancillary equipment15%1560

E-15 · Selects, installs and converts fuel systems, appliances and ancillary equipment

8 official exam questions · 32 in the practice bank

  • E-15.01 Selects appliances and ancillary equipment
  • E-15.02 Installs appliances and ancillary equipment
  • E-15.03 Installs fuel conversion components

E-16 · Selects and installs propane and natural gas storage, handling and dispensing systems

5 official exam questions · 20 in the practice bank

  • E-16.01 Selects propane and natural gas storage, handling and dispensing
  • E-16.02 Installs propane and natural gas storage, handling and dispensing

E-17 · Selects and installs other fuel storage, handling and dispensing systems

2 official exam questions · 8 in the practice bank

  • E-17.01 Selects other fuel storage, handling and dispensing systems
  • E-17.02 Installs other fuel storage, handling and dispensing systems
FTests and commissions fuel systems, appliances and ancillary equipment16%1664

F-18 · Tests fuel delivery systems

7 official exam questions · 28 in the practice bank

  • F-18.01 Selects testing equipment and procedures
  • F-18.02 Tests fuel piping and tubing systems

F-19 · Commissions fuel systems, appliances and ancillary equipment

9 official exam questions · 36 in the practice bank

  • F-19.01 Performs start-up procedures
  • F-19.02 Performs testing, adjusting and bal ancing procedures
  • F-19.03 Completes commissioning report and handover
GServices fuel systems, appliances and ancillary equipment18%1872

G-20 · Maintains fuel systems, appliances and ancillary equipment

8 official exam questions · 32 in the practice bank

  • G-20.01 Inspects system components and operation
  • G-20.02 Performs maintenance activities

G-21 · Repairs fuel systems, appliances and ancillary equipment

8 official exam questions · 32 in the practice bank

  • G-21.01 Diagnoses system components and operation
  • G-21.02 Replaces components
  • G-21.03 Verifies operation

G-22 · Decommissions fuel systems, appliances and ancillary equipment

2 official exam questions · 8 in the practice bank

  • G-22.01 Disconnects appliances and ancillary equipment
  • G-22.02 Removes appliances and ancillary equipment

Source: the official Gasfitter – Class B standard and exam breakdown. Check your own requirements with your province or territory.

Questions about Gasfitter – Class B exam prep

Study guide
Is there a free Gasfitter – Class B Red Seal practice test?

Yes. Gasfitter – Class B Exam 1 is a full practice exam of 100 questions with an explanation for every answer. It is free with a free account in every available trade: unlimited retakes, no expiry and no credit card. The same account plays Question Match with Exam 1. Without an account, try 12 sample questions, math formulas, 20 flashcards and Flashcard Match.

Is there a Gasfitter – Class B practice test with answers?

Yes. Every Gasfitter – Class B practice question comes with its correct answer and an explanation of why it is right. In the free 12-question sample, submit your answers to see the correct answers, the explanations and your score, with no account. Exam 1, free with a free account, and every paid exam also show your score by Major Work Activity. These are original practice questions, not real exam questions.

How many questions are on the Gasfitter – Class B Red Seal exam?

The official Gasfitter – Class B Red Seal exam has 100 multiple-choice questions. Each question has four options and one correct answer. The writing time is four hours and the pass mark is 70%: at least 70 of 100 questions correct.

What topics are on the Gasfitter – Class B Red Seal exam?

The published exam breakdown has 7 Major Work Activities (MWAs) or blocks: A, Performs common occupational skills (7 questions); B, Installs fuel piping and tubing systems (14 questions); C, Installs venting and air supply systems (15 questions); D, Installs controls and electrical systems (15 questions); E, Installs and converts fuel systems, appliances and ancillary equipment (15 questions); F, Tests and commissions fuel systems, appliances and ancillary equipment (16 questions); G, Services fuel systems, appliances and ancillary equipment (18 questions).

Can I challenge the Gasfitter – Class B Red Seal exam without an apprenticeship?

Yes. Experienced workers apply to their provincial or territorial authority as trade qualifiers (challengers in New Brunswick, a Trade Equivalency Assessment in Ontario); once it verifies your documented hands-on hours, you write the same 100-question Red Seal exam as a completing apprentice. Quebec has no challenge exam: where it certifies the trade, experienced workers earn a Quebec certificate first, by recognition of their hours or skills, and then enrol in its Red Seal Program. The federal Ellis Chart lists the hours each authority requires for this trade, from 4,500 in British Columbia to 6,000 in Prince Edward Island (read 2026-10-29); the table on this page shows every province. Buying practice material does not make you eligible; the authority decides.

How do your Gasfitter – Class B practice exams follow the official breakdown?

Every practice question maps to an MWA and task, and nearly every question maps to a specific subtask. Numbered practice exams match the published question count for each MWA. Mixed exams combine questions from your trade’s numbered exams; their topic distribution can vary.

What are Flashcard Match and Question Match?

Flashcard Match deals a board of Gasfitter – Class B flashcards on the left and their answers, shuffled, on the right; you match each card to its answer. Question Match does the same with Gasfitter – Class B practice exam questions. Every round deals a new mix, so there are more than 1,000 different rounds of each.

How many Gasfitter – Class B practice exams are included?

Pass Your Red Seal includes 4 practice exams and 400 original practice questions for Gasfitter – Class B. Study access includes answers, explanations, practice and timed modes, and results by topic. The practice-bank total covers all available exams; it is separate from the 100 questions on the official exam.

Are Gasfitter – Class B flashcards included?

Yes. Every Gasfitter – Class B plan includes 200 flashcards in two exam-weighted sets of 100 cards. Each set follows the Major Work Activity and task question counts of the official Red Seal Occupational Standard – Gasfitter – Class B (2024) exam breakdown. Review the answer, reasoning, exam trap and standard reference on each card, then use your flashcard score by Major Work Activity to focus your next review.

Can I try Gasfitter – Class B practice questions for free?

Yes. Try 12 free Gasfitter – Class B questions without an account or payment. The sample uses the same format as the full exams: answer one question at a time, navigate between questions, submit your answers, and review your score and explanations. Create a free account to take Exam 1, a full practice exam, in every available trade: unlimited retakes, no expiry and no credit card. Review explanations and your score by MWA, and play Question Match with Exam 1’s questions. Exams 2 onward, mixed exams, paid flashcards and full Flashcard Match and Question Match require paid access for that trade.

How much does Gasfitter – Class B study access cost?

Study access for Gasfitter – Class B costs $8.99 for 1 month or $14.99 for 12 months. Each plan covers this one trade. Pay once, or choose optional renewal with the 1 month plan: $8.99 for the first month, then $5.99 a month. Stop future renewals in your account.

Challenge the Gasfitter – Class B exam without an apprenticeship

How it works

Experienced workers in the gasfitter – class b trade can write this Red Seal exam as trade qualifiers once their province verifies enough hands-on experience. The hours below are the figures each authority reports to the federal Ellis Chart, read 29 October 2026; the trade’s own form or profile sets the final rule, and each province’s guide has the forms, fees and steps.

Experience required to challenge the Gasfitter – Class B Red Seal exam
Province or territory, with its guideHours to challengeApprenticeship and certification
British Columbia4,500Apprenticeship 3,600 hours · compulsory certification
Alberta4,680Apprenticeship 3,600 hours · compulsory certification
SaskatchewanNo challenge route
Manitoba
Domestic Gasfitter
5,400Apprenticeship 3,600 hours · voluntary certification
OntarioNot shown
QuebecQuebec certificate firstCompulsory certification
New Brunswick5,400Apprenticeship 3,600 hours · voluntary certification
Nova Scotia5,400Apprenticeship 3,600 hours · voluntary certification
Prince Edward Island6,000Voluntary certification
Newfoundland and Labrador5,400Voluntary certification
Yukon
Gasfitter (Second Class)
5,400Apprenticeship 3,600 hours · voluntary certification
Northwest Territories5,400Apprenticeship 3,600 hours · voluntary certification
Nunavut
Gasfitter (Second Class)
5,400Apprenticeship 3,600 hours · voluntary certification

Source: Ellis Chart, Gasfitter – Class B, published by the Canadian Council of Directors of Apprenticeship. Each authority sets and changes its own rules; confirm the current figure on its page before you apply.