Pass Your Red Seal
MathOnline Red Seal Exam Preparation, built on official standards
MathGas meter timing and pressure correctionHeatSee study access
All math

Gas meter timing and pressure correction

Use consistent pressure units and the specified base condition. The simple pressure-only model assumes unchanged temperature and compressibility.

The formulas
  • Volume rate = dial volume × 3600 / seconds per revolution × pressure factor
  • Pressure factor = (atmospheric + gauge pressure) / base absolute pressure
  • Input heat rate = corrected volume rate × stated heating value
How to do it
  1. 1Time a stated meter volume and convert to volume per hour.
  2. 2Correct to the stated base pressure using absolute pressure.
  3. 3Apply heating value only when an energy input is requested.
Worked example

A 1 ft³ dial turning in 36 s gives 100 ft³/h uncorrected. At pressure factor 1.1 the corrected rate is 110 ft³/h.

The usual mistakes
  • Gauge pressure alone cannot be used as the numerator of an absolute-pressure ratio.
  • Real billing/precision measurement may also compensate temperature and compressibility.

Pass Your Red Seal’s lessons and practice are independent study material. Source: Red Seal: formula resources by trade

Try one

A 2 ft³ dial turns once in 72 s. At pressure factor 1.0, find gas rate.

This topic

The lesson and a worked example
Practice questions in this topic12
Mixed practiceEvery math topic

Mixed practice

Every math topic

Keys this topic uses

  • ()Works the part in brackets first
  • ALPHA=Types ANS, the last answer

Calculator skill: order of operations

Topic practice2 questions · 0 done