Pass Your Red Seal
MathOnline Red Seal Exam Preparation, built on official standards
MathRTDs, lead resistance and temperatureInstrumentationSee study access
All math

RTDs, lead resistance and temperature

Illustrative Pt100 model: R₀=100 Ω at 0 °C and α=0.00385/°C. This linear approximation is for exercises, not a replacement for the configured sensor curve.

The formulas
  • R ≈ R₀(1 + αT)
  • T ≈ (R/R₀ − 1) / α
  • Two-wire measured resistance = sensor resistance + both lead resistances
How to do it
  1. 1Confirm the sensor type, curve and wiring configuration.
  2. 2Remove known lead resistance before using the simplified inverse relation.
Worked example

At 50 °C the linear model gives 100 × (1 + 0.00385 × 50) = 119.25 Ω. Two 1 Ω leads would make a two-wire measurement 121.25 Ω.

The usual mistakes
  • Three-wire compensation depends on matched lead resistance; four-wire measurement largely separates excitation and voltage-sense paths.
  • Use the full applicable curve for precision work.

Pass Your Red Seal’s lessons and practice are independent study material. Source: OpenStax: resistivity and resistance (temperature dependence)

Try one

Under the stated linear Pt100 model, what resistance corresponds to 100 °C?

This topic

The lesson and a worked example
Practice questions in this topic12
Mixed practiceEvery math topic

Mixed practice

Every math topic

Keys this topic uses

  • ()Works the part in brackets first
  • ALPHA=Types ANS, the last answer

Calculator skill: order of operations

Topic practice2 questions · 0 done