Pass Your Red Seal
MathOnline Red Seal Exam Preparation, built on official standards

Heavy Duty Equipment Technician formula sheet and conversions

MathReference40 formulas · 69 conversions · 63 acronyms
All math

On the exam

Official formula sheet
None for this trade
Conversions
Not given: learn them
Acronyms
You get the list
Calculator
The same calculator as here

On the exam

Formula sheetNone for this trade
CalculatorThe same as here

Formulas

40 formulas

The Red Seal Program does not publish a formula sheet for this trade, so these are the formulas its math lessons use.

°F = 1.8 × °C + 32
°C = (°F − 32) / 1.8
K = °C + 273.15
Δ°F = 1.8 × Δ°C
1 US gal = 3.785411784 L; 1 Imperial gal = 4.54609 L
RectangleA = LW; perimeter = 2(L+W)
TriangleA = bh/2; perimeter = a+b+c
CircleA = πr² = πd²/4; C = πd
BoxV = LWH
CylinderV = πr²h
SphereV = 4πr³/3
Cone or pyramidV = base area × h/3
Triangular wedgeV = LWH/2
1 m³ = 1000 L
Cylinder side = 2πrh
Cylinder with one end = 2πrh + πr²
Closed cylinder = 2πrh + 2πr²
Closed box = 2(LW + LH + WH)
Open box = LW + 2LH + 2WH
Sphere = 4πr²
Cone lateral area = πrs
Pyramid lateral area = perimeter of base × slant height / 2
c² = a² + b²
sin θ = opposite/hypotenuse
cos θ = adjacent/hypotenuse
tan θ = opposite/adjacent
θ = atan(rise/run)
Offset travel = offset / sin θ
Arc length = πrθ/180 = πdθ/360
Sector pattern angle = 360 × base radius / slant radius
Equivalent formpattern angle = 180 × base diameter / slant radius
Grade (%) = rise/run × 100
Rise = run × unit rise/unit run
Symmetrical roof run = span/2
Rafter line length = √(run² + rise²)
Unit line length (per 12 of run) = √(12² + unit rise²)
New quantity = original quantity × scale factor
Scale factor = required yield / original yield
With p% addedfinal = original × (1+p/100)
Baker’s percentage = ingredient mass / flour mass × 100
Temperature and unit conversion
°F = 1.8 × °C + 32
°C = (°F − 32) / 1.8
K = °C + 273.15
Δ°F = 1.8 × Δ°C
1 US gal = 3.785411784 L; 1 Imperial gal = 4.54609 L
Areas, perimeter and circumference
RectangleA = LW; perimeter = 2(L+W)
TriangleA = bh/2; perimeter = a+b+c
CircleA = πr² = πd²/4; C = πd
Volumes, capacity and material quantities
BoxV = LWH
CylinderV = πr²h
SphereV = 4πr³/3
Cone or pyramidV = base area × h/3
Triangular wedgeV = LWH/2
1 m³ = 1000 L
Surface area of vessels and insulation
Cylinder side = 2πrh
Cylinder with one end = 2πrh + πr²
Closed cylinder = 2πrh + 2πr²
Closed box = 2(LW + LH + WH)
Open box = LW + 2LH + 2WH
Sphere = 4πr²
Cone lateral area = πrs
Pyramid lateral area = perimeter of base × slant height / 2
Pythagoras, trigonometry and offsets
c² = a² + b²
sin θ = opposite/hypotenuse
cos θ = adjacent/hypotenuse
tan θ = opposite/adjacent
θ = atan(rise/run)
Offset travel = offset / sin θ
Arc lengths and developed patterns
Arc length = πrθ/180 = πdθ/360
Sector pattern angle = 360 × base radius / slant radius
Equivalent formpattern angle = 180 × base diameter / slant radius
Grade, roof rise and run
Grade (%) = rise/run × 100
Rise = run × unit rise/unit run
Symmetrical roof run = span/2
Rafter line length = √(run² + rise²)
Unit line length (per 12 of run) = √(12² + unit rise²)
Percentages, recipe scaling and quantities
New quantity = original quantity × scale factor
Scale factor = required yield / original yield
With p% addedfinal = original × (1+p/100)
Baker’s percentage = ingredient mass / flour mass × 100

On the exam

ConversionsNot given: learn them

Conversions

69 conversions
1 psi6.895 kPa
1 kPa0.1450 psi
1 bar100 kPa
1 bar14.50 psi
1 atm101.3 kPa
1 atm14.70 psi
1 in w.c.249.1 Pa
1 ft of water0.4335 psi
1 in Hg3.386 kPa
1 lbf4.448 N
1 kN224.8 lbf
1 L/s60 L/min
1 L/s3.6 m³/h
1 L/s15.85 US gpm
1 L/s13.20 imp gpm
1 US gpm3.785 L/min
1 imp gpm4.546 L/min
1 cfm0.4719 L/s
1 cfm1.699 m³/h
1 m³/h0.5886 cfm
1 N·m0.7376 lb·ft
1 N·m8.851 lb·in
1 lb·ft1.356 N·m
1 lb·ft12 lb·in
1 lb·in0.1130 N·m
1 kgf·m9.807 N·m
1 in³16.39 cm³
1 L61.02 in³
1 US qt0.9464 L
1 US gal3.785 L
mpg (US)235.2 ÷ L/100 km
mpg (imp)282.5 ÷ L/100 km
1 lb·ft1.356 N·m
1 hp0.746 kW
1 mph1.609 km/h
1 psi6.895 kPa
1 hp746 W
1 kW1.341 hp
1 kW3 412 Btu/h
1 Btu/h0.2931 W
1 Btu1.055 kJ
1 ton of refrigeration12 000 Btu/h
1 ton of refrigeration3.517 kW
1 kWh3.6 MJ
1 therm100 000 Btu
1 boiler hp33 475 Btu/h
1 kg2.205 lb
1 lb0.4536 kg
1 lb16 oz
1 oz28.35 g
1 t (tonne)1 000 kg
1 t (tonne)2 205 lb
1 short ton2 000 lb
1 short ton907.2 kg
°C to °F× 1.8, then + 32
°F to °C− 32, then ÷ 1.8
°C to K+ 273.15
A difference of 1 °C1.8 °F
Water freezes0 °C = 32 °F
Water boils (sea level)100 °C = 212 °F
Power (W)V × A
1 kW1 000 W
1 kVA1 000 VA
1 hp746 W
1 mA0.001 A
1 mV0.001 V
1 kΩ1 000 Ω
1 MΩ1 000 000 Ω
1 kWh1 kW for 1 hour
Pressure and force
1 psi6.895 kPa
1 kPa0.1450 psi
1 bar100 kPa
1 bar14.50 psi
1 atm101.3 kPa
1 atm14.70 psi
1 in w.c.249.1 Pa
1 ft of water0.4335 psi
1 in Hg3.386 kPa
1 lbf4.448 N
1 kN224.8 lbf
Flow
1 L/s60 L/min
1 L/s3.6 m³/h
1 L/s15.85 US gpm
1 L/s13.20 imp gpm
1 US gpm3.785 L/min
1 imp gpm4.546 L/min
1 cfm0.4719 L/s
1 cfm1.699 m³/h
1 m³/h0.5886 cfm
Torque
1 N·m0.7376 lb·ft
1 N·m8.851 lb·in
1 lb·ft1.356 N·m
1 lb·ft12 lb·in
1 lb·in0.1130 N·m
1 kgf·m9.807 N·m
Vehicle and engine
1 in³16.39 cm³
1 L61.02 in³
1 US qt0.9464 L
1 US gal3.785 L
mpg (US)235.2 ÷ L/100 km
mpg (imp)282.5 ÷ L/100 km
1 lb·ft1.356 N·m
1 hp0.746 kW
1 mph1.609 km/h
1 psi6.895 kPa
Power and energy
1 hp746 W
1 kW1.341 hp
1 kW3 412 Btu/h
1 Btu/h0.2931 W
1 Btu1.055 kJ
1 ton of refrigeration12 000 Btu/h
1 ton of refrigeration3.517 kW
1 kWh3.6 MJ
1 therm100 000 Btu
1 boiler hp33 475 Btu/h
Mass
1 kg2.205 lb
1 lb0.4536 kg
1 lb16 oz
1 oz28.35 g
1 t (tonne)1 000 kg
1 t (tonne)2 205 lb
1 short ton2 000 lb
1 short ton907.2 kg
Temperature
°C to °F× 1.8, then + 32
°F to °C− 32, then ÷ 1.8
°C to K+ 273.15
A difference of 1 °C1.8 °F
Water freezes0 °C = 32 °F
Water boils (sea level)100 °C = 212 °F
Electrical
Power (W)V × A
1 kW1 000 W
1 kVA1 000 VA
1 hp746 W
1 mA0.001 A
1 mV0.001 V
1 kΩ1 000 Ω
1 MΩ1 000 000 Ω
1 kWh1 kW for 1 hour

On the exam

AcronymsYou get the list

Acronyms

63 acronyms

The following acronyms used in this trade may be on its Red Seal exam. They will also be provided with the exam sitting. The official list (PDF)

A/Cair conditioning
ABSanti-lock brake system
ACalternating current
AFRair-fuel ratio
BCMbody control module
BEVbattery electric vehicle
CANcontroller area network
CCAcold cranking amperes
COcarbon monoxide
CPScrankshaft position sensor
DCdirect current
DCVdirectional control valve
DEFdiesel exhaust fluid
DMMdigital multimeter
DOCdiesel oxidation catalyst
DPFdiesel particulate filter
ECMelectronic control module
EGRexhaust gas recirculation
EPROMerasable programmable read-only memory
FOPSfalling object protective structure
GPSglobal positioning system
HMUhand metering unit
hrhour
HVACheating, ventilation and air conditioning
ICEinternal combustion engine
in.inch
IRinfrared
JICJoint Industrial Council
kPakilopascal
kWkilowatt
LEDlight-emitting diode
LOTOlock-out / tag-out
LPGliquefied petroleum gas
MAPmanifold absolute pressure
minminute
mmmillimetre
NOxnitrous oxide
NPTNational Pipe Taper Thread
OEMoriginal equipment manufacturer
ppmparts per million
psipounds per square inch
psiapounds per square inch absolute
psigpounds per square inch gauge
PTOpower take-off
°Cdegree Celsius
°Fdegree Fahrenheit
ROPSroll-over protective structure
rpmrevolutions per minute
ssecond
SAESociety of Automotive Engineers
SAHRspring-applied hydraulic released
SAHRSpring Applied Hydraulic Release
SCRselective catalytic reduction
SDSsafety data sheet
TDCtop dead centre
TDGtransportation of dangerous goods
TPSthrottle position sensor
UVultraviolet
Vvolt
VGTvariable geometry turbo charger
VINvehicle identification number
VVTvariable valve timing
WHMISWorkplace Hazardous Materials Information System
°Cdegree Celsius
°Fdegree Fahrenheit
A/Cair conditioning
ABSanti-lock brake system
ACalternating current
AFRair-fuel ratio
BCMbody control module
BEVbattery electric vehicle
CANcontroller area network
CCAcold cranking amperes
COcarbon monoxide
CPScrankshaft position sensor
DCdirect current
DCVdirectional control valve
DEFdiesel exhaust fluid
DMMdigital multimeter
DOCdiesel oxidation catalyst
DPFdiesel particulate filter
ECMelectronic control module
EGRexhaust gas recirculation
EPROMerasable programmable read-only memory
FOPSfalling object protective structure
GPSglobal positioning system
HMUhand metering unit
hrhour
HVACheating, ventilation and air conditioning
ICEinternal combustion engine
in.inch
IRinfrared
JICJoint Industrial Council
kPakilopascal
kWkilowatt
LEDlight-emitting diode
LOTOlock-out / tag-out
LPGliquefied petroleum gas
MAPmanifold absolute pressure
minminute
mmmillimetre
NOxnitrous oxide
NPTNational Pipe Taper Thread
OEMoriginal equipment manufacturer
ppmparts per million
psipounds per square inch
psiapounds per square inch absolute
psigpounds per square inch gauge
PTOpower take-off
ROPSroll-over protective structure
rpmrevolutions per minute
ssecond
SAESociety of Automotive Engineers
SAHRspring-applied hydraulic released
SAHRSpring Applied Hydraulic Release
SCRselective catalytic reduction
SDSsafety data sheet
TDCtop dead centre
TDGtransportation of dangerous goods
TPSthrottle position sensor
UVultraviolet
Vvolt
VGTvariable geometry turbo charger
VINvehicle identification number
VVTvariable valve timing
WHMISWorkplace Hazardous Materials Information System