Steam drip legs and condensate
Online Red Seal Exam Preparation, built on official standardsSPECIALIST STUDYSteam drip legs and condensateField practiceView study access
Specialist studyA steam-main drip leg collects condensate for a trap. A DP wet leg provides a reference head for level measurement; their purposes differ.
THE FORMULAS
- Condensate formation rate ≈ heat loss rate / latent heat (consistent units)
HOW TO DO IT
- 1Identify low points, risers and equipment requiring drainage from the system layout.
- 2Check collector arrangement and trap differential pressure using the applicable steam-system guidance.
- 3Distinguish condensate-driven water hammer from thermal movement or control oscillation.
Worked example
With a stated 10 kW heat loss and 2000 kJ/kg latent heat, condensate forms at 10/2000=0.005 kg/s=18 kg/h. Trap selection must also allow for startup and operating conditions.
THE USUAL MISTAKES
- Spacing and dimensions depend on the design and manufacturer; a rule of thumb is not a universal code requirement.
- Water hammer can damage equipment; drainage is a system design concern.
SOURCES AND FURTHER READING
Spirax Sarco: steam mains and drainageSpirax Sarco: thermodynamic steam trapsTLV: trap inspection instruments
Pass Your Red Seal’s lessons and practice are independent study material. Manufacturer topics extend trade learning; they are not a claim about the content of an official exam.
TRY ONE · FREE
What is the primary purpose of installing drip legs at low points and at regular intervals along a steam distribution main?
Topic practice15 practice questions
Topic practice
15 practice questions- Choose a short set or the full topic
- Review wrong answers and retry
- Resume in this browser tab