Pass Your Red Seal

Cavitation and the vena contracta

Online Red Seal Exam Preparation, built on official standards
SPECIALIST STUDYCavitation and the vena contractaField practiceView study access
Specialist study

The vena contracta is the contracted jet region after a restriction. Cavitation involves bubble collapse after pressure recovery; flashing leaves a vapour phase downstream.

THE FORMULAS

  • Continuity: Av = constant
  • Bernoulli: P + ρv²/2 + ρgz = constant (idealized streamline)
  • Vapour forms where local absolute pressure falls below vapour pressure

HOW TO DO IT

  1. Compare local absolute pressure with the fluid’s vapour pressure at its actual temperature.
  2. Examine downstream recovery to distinguish collapse from persistent flashing.
  3. Relate the symptoms to the valve/pump application and manufacturer sizing guidance.

Worked example

If a liquid has a vapour pressure of 3 kPa absolute, a 2 kPa local minimum can create vapour. Recovery to 20 kPa permits collapse; remaining below 3 kPa supports flashing.

THE USUAL MISTAKES

  • Upstream gauge pressure alone does not establish cavitation conditions.
  • Real restrictions dissipate energy; the ideal Bernoulli equation is a learning model.

SOURCES AND FURTHER READING

Pass Your Red Seal’s lessons and practice are independent study material. Manufacturer topics extend trade learning; they are not a claim about the content of an official exam.

TRY ONE · FREE

The vena contracta in a flowing fluid is best described as:

Topic practice10 practice questions

Topic practice

10 practice questions
  • Choose a short set or the full topic
  • Review wrong answers and retry
  • Resume in this browser tab
Topic practice10 questions · 0 done